Transformer Ratio Calculator

Transformer Ratio Calculator from Gizcalc helps you estimate results quickly within the Engineering category.

  • Instant results
  • Charts & tables
  • Save & compare
  • Private – runs in your browser
Turns Ratio —

Sample inputs are pre-filled so you can see a result quickly. Results are estimates only and may not be accurate because prices, interest rates, taxes, fees, fuel costs, tariffs, market returns, medical costs, and local rules can change. Please verify current values before making financial, tax, legal, medical, or business decisions.

Formula used

Np ÷ Ns = Vp ÷ Vs = Is ÷ Ip

  • Full-load current (3-phase) = kVA × 1,000 ÷ (√3 × V)
  • Full-load current (1-phase) = kVA × 1,000 ÷ V

About the Transformer Ratio Calculator

What is the Transformer Ratio Calculator?

A transformer's voltage ratio equals its transformer turns ratio, and currents change in the opposite ratio. This calculator gives the ratio, the secondary turns if you know the primary turns, and the full-load current on each side.

It supports single-phase and three-phase transformers, such as the common 11 kV / 433 V distribution transformer.

How to use the Transformer Ratio Calculator

  1. Type (sample: Three-phase)
  2. Primary Voltage (V) (sample: 11,000)
  3. Secondary Voltage (V) (sample: 433)
  4. Rating (kVA) (sample: 100)
  5. Primary Turns (0 if unknown) (sample: 0)
  6. Press Calculate Transformer Ratio (results also refresh as you type). The result card shows the Turns Ratio, along with Ratio as a number, Primary full-load current, Secondary full-load current and Type.

Formula used

Np ÷ Ns = Vp ÷ Vs = Is ÷ Ip

  • Full-load current (3-phase) = kVA × 1,000 ÷ (√3 × V)
  • Full-load current (1-phase) = kVA × 1,000 ÷ V

Distribution transformers use 433 V (not 415 V) secondaries to allow for voltage drop under load.

Worked example

These are the sample values already filled in the calculator above, and the result it returns for them:

InputSample value
TypeThree-phase
Primary Voltage (V)11,000
Secondary Voltage (V)433
Rating (kVA)100
Primary Turns (0 if unknown)0
ResultValue
Turns Ratio25.404 : 1
Ratio as a number25.4042
Primary full-load current5.25 A
Secondary full-load current133.34 A
TypeStep-down

Tips for using the Transformer Ratio Calculator

  • Use the full-load current to size cables and protection on each side.
  • Real transformers have small losses, so the actual secondary voltage drops slightly under load.

Frequently asked questions

About 5.25 A on the 11 kV side and 133 A on the 433 V side.

230 ÷ 12 ≈ 19.2 : 1.

Yes, the secondary current is higher by the same ratio that voltage is lower.