U-Value —

Sample inputs are pre-filled so you can see a result quickly. Results are estimates only and may not be accurate because prices, interest rates, taxes, fees, fuel costs, tariffs, market returns, medical costs, and local rules can change. Please verify current values before making financial, tax, legal, medical, or business decisions.

Formula used

U = 1 ÷ (R_si + Σ(t ÷ k) + R_so)

  • t ÷ k = thickness (m) ÷ conductivity for each layer
  • Surface resistances = walls 0.13 + 0.04, roofs 0.10 + 0.04 m²·K/W

About the Thermal Resistance Calculator

What is the Thermal Resistance Calculator?

The U-value measures how much heat passes through a wall or roof per square metre per degree. Lower is better for comfort and air-conditioning bills.

List each layer – plaster, brick, insulation – with its thickness and conductivity. The calculator adds their resistances and the surface air-film resistances.

How to use the Thermal Resistance Calculator

  1. Layers (one per line: name, thickness in mm, conductivity in W/m·K) — one layer per line: name, thickness in mm, conductivity in W/m·K. For example: Brick, 230, 0.81. (sample: Cement plaster, 12, 0.72 Brick, 230, 0.81 Cement plaster, 12, 0.72)
  2. Surface Resistances (sample: Wall (inside 0.13 + outside 0.04))
  3. Area (m²) (sample: 10)
  4. Indoor–Outdoor Temperature Difference (°C) (sample: 12)
  5. Press Calculate R-Value and U-Value (results also refresh as you type). The result card shows the U-Value, along with Total thermal resistance (R), Heat flow through the area and Reference.

Formula used

U = 1 ÷ (R_si + Σ(t ÷ k) + R_so)

  • t ÷ k = thickness (m) ÷ conductivity for each layer
  • Surface resistances = walls 0.13 + 0.04, roofs 0.10 + 0.04 m²·K/W

ECBC 2017 sets maximum U-values for walls and roofs of air-conditioned commercial buildings.

Worked example

These are the sample values already filled in the calculator above, and the result it returns for them:

InputSample value
Layers (one per line: name, thickness in mm, conductivity in W/m·K)Cement plaster, 12, 0.72 Brick, 230, 0.81 Cement plaster, 12, 0.72
Surface ResistancesWall (inside 0.13 + outside 0.04)
Area (m²)10
Indoor–Outdoor Temperature Difference (°C)12
ResultValue
U-Value2.052 W/m²·K
Total thermal resistance (R)0.487 m²·K/W
Heat flow through the area246.3 W
ReferenceECBC 2017 limits for air-conditioned buildings: walls about 0.40–0.63 and roofs about 0.33 W/m²·K

Tips for using the Thermal Resistance Calculator

  • Adding 50 mm of EPS or PUF insulation can cut a roof's U-value by more than half.
  • Air gaps and reflective foils add resistance but need proper detailing.

Frequently asked questions

About 2.05 W/m²·K.

R is resistance to heat flow; U is its inverse, the rate of heat flow.

About 0.33 W/m²·K for most air-conditioned commercial buildings.