Skip to content
Advertisement
Hosinger Special Offer

Soil Bearing Capacity Calculator

Soil Bearing Capacity Calculator from Gizcalc helps you estimate results quickly within the Engineering category.

  • Instant results
  • Charts & tables
  • Save & compare
  • Private – runs in your browser
Net Safe Bearing Capacity —

Sample inputs are pre-filled so you can see a result quickly. Results are estimates only and may not be accurate because prices, interest rates, taxes, fees, fuel costs, tariffs, market returns, medical costs, and local rules can change. Please verify current values before making financial, tax, legal, medical, or business decisions.

Formula used

q_ult = c Nc sc + q Nq sq + 0.5 γ B Nγ sγ

  • Nq = e^(π tan φ) × tan²(45° + φ/2)
  • Nc = (Nq − 1) cot φ (5.14 when φ = 0)
  • Nγ = 2 (Nq + 1) tan φ
  • Net safe capacity = (q_ult − γ Df) ÷ factor of safety

About the Soil Bearing Capacity Calculator

What is the Soil Bearing Capacity Calculator?

This bearing capacity calculator uses the general bearing capacity equation of IS 6403, with bearing capacity factors Nc, Nq and Nγ and shape factors for strip, square and circular footings.

Enter soil properties from a geotechnical report – cohesion, friction angle and unit weight – with the footing width and depth.

How to use the Soil Bearing Capacity Calculator

  1. Cohesion c (kN/m²) (sample: 10)
  2. Friction Angle φ (°) (sample: 30)
  3. Soil Unit Weight γ (kN/m³) (sample: 18)
  4. Footing Width B (m) (sample: 1.5)
  5. Footing Depth Df (m) (sample: 1.2)
  6. Footing Shape (sample: Square)
  7. Factor of Safety (sample: 3)
  8. Press Calculate Bearing Capacity (results also refresh as you type). The result card shows the Net Safe Bearing Capacity, along with Ultimate bearing capacity, Nc, Nq, Nγ, Overburden pressure and Scope.

Formula used

q_ult = c Nc sc + q Nq sq + 0.5 γ B Nγ sγ

  • Nq = e^(π tan φ) × tan²(45° + φ/2)
  • Nc = (Nq − 1) cot φ (5.14 when φ = 0)
  • Nγ = 2 (Nq + 1) tan φ
  • Net safe capacity = (q_ult − γ Df) ÷ factor of safety

Settlement often governs before bearing failure; always get a soil investigation for buildings.

Worked example

These are the sample values already filled in the calculator above, and the result it returns for them:

InputSample value
Cohesion c (kN/m²)10
Friction Angle φ (°)30
Soil Unit Weight γ (kN/m³)18
Footing Width B (m)1.5
Footing Depth Df (m)1.2
Footing ShapeSquare
Factor of Safety3
ResultValue
Net Safe Bearing Capacity363 kN/m²
Ultimate bearing capacity1,110.72 kN/m²
Nc, Nq, Nγ30.14, 18.4, 22.4
Overburden pressure21.6 kN/m²
ScopeIgnores depth, inclination and water-table factors; settlement must also be checked

Tips for using the Soil Bearing Capacity Calculator

  • A high water table can halve the γ terms; adjust with water-table factors.
  • Use a factor of safety of 2.5–3 on the ultimate capacity.

Frequently asked questions

The pressure a soil can carry with an adequate margin against shear failure – commonly 100–300 kN/m² for Indian soils.

For a strip footing at the surface, q_ult ≈ 5.14 × 50 = 257 kN/m², or about 86 kN/m² safe.

Shape factors account for three-dimensional failure, which mobilises more soil.